Ribbon: Track-side Design > Height Reduction
The function Disband feeder section deletes the allocation
of the feeder to the catenary height reduction.
Intention
|
Reassign the feeder from the catenary height
reduction.
|
Instructions
|
- Run the Disband
Feeder Section function.
- Select the
catenary height reduction.
- Select the
feeder, where the catenary height reduction should be reassigned.
- Confirm with OK.
|
Result
|
Sicat Master will reassign the feeder from the
catenary height reduction and save the data into the database.
|
Note: This function was
maintained for compatibility reasons. The better treatment and display
variation is associated to one longitudinal profile or several catenary height
reductions and feeders.